Performed forensic investigation of cracks in concrete slab on grade and precast cement terrazzo stair treads and exterior wall efflorescence at the 60,000 SF quarantine facility located on the grounds of Miami International Airport. Investigation required partial wall demolition and bore scope examination to locate source of water entry. Analysis determined water entry at parapet coping.